{
  "id": "voltpeer-layout-transport-kinetics-audit",
  "version": "2.0.0",
  "name": "Kinetics: impedance, transport and assumptions",
  "name_zh": "动力学：阻抗、输运与假设审查",
  "author": "VoltPeer",
  "license": "MIT",
  "category": "layout",
  "status": "community",
  "description": "8 empty editable panels. A near-square impedance lead supports equal axis scales; DRT, CV, diffusion and transport checks sit independently beside it.",
  "description_zh": "8 个空白可编辑面板。近方形阻抗主图保持等比例；DRT、CV、扩散与输运在侧边独立核对。",
  "created_at": "2026-10-03",
  "updated_at": "2026-10-03",
  "tags": [
    "original-layout",
    "mechanism",
    "empty-panels"
  ],
  "source": "Original VoltPeer empty-panel layout; literature informs evidence roles only. No paper geometry, images or data copied.",
  "permissions": {
    "public_display": true,
    "registry": true,
    "automated_testing": true,
    "model_training": false
  },
  "template_collection": "voltpeer-layouts-20",
  "scientific_review": "not_claimed",
  "research_topic": "mechanism",
  "panel_count": 8,
  "roles": [
    "Cell & protocol",
    "EIS & fit check",
    "DRT & uncertainty",
    "CV & scan sequence",
    "Diffusion assumptions",
    "Measured transport",
    "Discriminating controls",
    "Data & uncertainty audit"
  ],
  "minimum_width_mm": 180,
  "minimum_font_pt": 8,
  "canvas": {
    "width_mm": 180,
    "height_mm": 121.5,
    "margin_mm": 4.05,
    "gutter_mm": 2.025
  },
  "grid": {
    "rows": 4,
    "cols": 4,
    "row_weights": [
      0.42,
      1.1,
      1.1,
      0.7
    ],
    "col_weights": [
      1,
      1,
      1,
      1
    ]
  },
  "panels": [
    {
      "label": "a",
      "role": "Cell & protocol",
      "role_zh": "电池与测试条件",
      "short_label": "Test conditions",
      "short_label_zh": "测试条件",
      "evidence_type": "protocol",
      "required_input": "Electrodes, loading, N/P or Li inventory, electrolyte amount, temperature, voltage window and current basis.",
      "row": 1,
      "col": 1,
      "rowspan": 1,
      "colspan": 4
    },
    {
      "label": "b",
      "role": "EIS & fit check",
      "role_zh": "阻抗与拟合检查",
      "short_label": "EIS & residuals",
      "short_label_zh": "EIS 与残差",
      "evidence_type": "eis",
      "required_input": "Frequency and complex Z from the same test; declared circuit, residuals, equal Nyquist scales and stationarity checks.",
      "row": 2,
      "col": 1,
      "rowspan": 2,
      "colspan": 2
    },
    {
      "label": "c",
      "role": "DRT & uncertainty",
      "role_zh": "DRT 与不确定性",
      "short_label": "DRT uncertainty",
      "short_label_zh": "DRT 不确定性",
      "evidence_type": "drt",
      "required_input": "Same EIS data, inversion/regularisation, sensitivity and residuals; peaks do not identify a mechanism by themselves.",
      "row": 2,
      "col": 3,
      "rowspan": 1,
      "colspan": 1
    },
    {
      "label": "d",
      "role": "CV & scan sequence",
      "role_zh": "CV 与扫速序列",
      "short_label": "CV sequence",
      "short_label_zh": "CV 序列",
      "evidence_type": "cv",
      "required_input": "Scan direction/rate, electrode basis and potential reference; report fitting assumptions.",
      "row": 2,
      "col": 4,
      "rowspan": 1,
      "colspan": 1
    },
    {
      "label": "e",
      "role": "Diffusion assumptions",
      "role_zh": "扩散分析与假设",
      "short_label": "Diffusion assumptions",
      "short_label_zh": "扩散假设",
      "evidence_type": "diff",
      "required_input": "Geometry, active area, pulse/relaxation intervals and validity domain; missing inputs stop derived D estimates.",
      "row": 3,
      "col": 3,
      "rowspan": 1,
      "colspan": 1
    },
    {
      "label": "f",
      "role": "Measured transport",
      "role_zh": "实测输运性质",
      "short_label": "Measured transport",
      "short_label_zh": "实测输运",
      "evidence_type": "transport",
      "required_input": "Conductivity/viscosity or diffusion with temperature, concentration and method; not interchangeable quantities.",
      "row": 3,
      "col": 4,
      "rowspan": 1,
      "colspan": 1
    },
    {
      "label": "g",
      "role": "Discriminating controls",
      "role_zh": "区分机制的对照",
      "short_label": "Mechanism controls",
      "short_label_zh": "区分性对照",
      "evidence_type": "control",
      "required_input": "Independent variable and matched baseline/negative control; correlation alone is insufficient.",
      "row": 4,
      "col": 1,
      "rowspan": 1,
      "colspan": 2
    },
    {
      "label": "h",
      "role": "Data & uncertainty audit",
      "role_zh": "数据与不确定性检查",
      "short_label": "Data & uncertainty",
      "short_label_zh": "数据与不确定性",
      "evidence_type": "audit",
      "required_input": "Raw sources, exclusions, units, normalisation and uncertainty propagation; no invented missing data.",
      "row": 4,
      "col": 3,
      "rowspan": 1,
      "colspan": 2
    }
  ],
  "evidence_sources": [
    {
      "title": "Dynamic doping and interphase stabilization for cobalt-free and high-voltage Lithium metal batteries",
      "doi": "10.1038/s41467-025-58110-z",
      "url": "https://www.nature.com/articles/s41467-025-58110-z",
      "figures": "Figure 4",
      "checked": "Publisher Figure 4 caption",
      "checked_at": "2026-10-02",
      "learning_note": "Link depth-resolved chemistry, EIS/DRT and matched microscopy without treating a single technique as causal proof.",
      "scope": "Evidence organisation only. No paper images, data, geometry or quantitative claims copied.",
      "rights_scope": "Citation only. Paper copyright/licence is independent; no figure pixels, geometry, data or article text redistributed."
    },
    {
      "title": "Aligning academia and industry for unified battery performance metrics",
      "doi": "10.1038/s41467-018-07599-8",
      "url": "https://www.nature.com/articles/s41467-018-07599-8",
      "figures": "Commentary; performance reporting",
      "checked": "Publisher abstract",
      "checked_at": "2026-10-02",
      "learning_note": "Use application-relevant conditions; capacity, efficiency and cyclability answer different questions.",
      "scope": "Evidence organisation only. No paper images, data, geometry or quantitative claims copied.",
      "rights_scope": "Citation only. Paper copyright/licence is independent; no figure pixels, geometry, data or article text redistributed."
    }
  ],
  "evidence_flow": "Measured response → model checks → limits",
  "evidence_flow_zh": "实测响应 → 模型检查 → 适用边界",
  "geometry_rationale": "A near-square impedance lead supports equal axis scales; DRT, CV, diffusion and transport checks sit independently beside it.",
  "geometry_rationale_zh": "近方形阻抗主图保持等比例；DRT、CV、扩散与输运在侧边独立核对。",
  "recommended_use": "Editable empty canvas only. Insert your actual figures; keep labels, units, scale bars, controls and sources. Use only panels relevant to your claim; no mandatory experiment checklist or causal proof is implied.",
  "recommended_use_zh": "空白可编辑画布。请放入你自己的真实图件，保留单位、比例尺、对照与来源。按论点增减面板；布局不是必须凑齐的实验清单，也不证明因果关系。",
  "input_kind": "panel_manifest_not_experimental_data",
  "preview_scope": "Empty labelled panels only; no traces, numerical axes, molecules or specimen images.",
  "layout_renderer": "native-empty-panels-v2",
  "derived_from": [
    "community:research-transport-kinetics-audit@1.0.0"
  ]
}
